Related Products

Related Products

4Fr 5Fr 6Fr -10 French 9cm 11cm 23cm vascular guide wire introduction catheter, percutaneous femoral introducer sheath kit

The introducer set is intended for percutaneous introduction of guide wire or catheter into the vascular system through introducer needle. The introducer set should be used only by physicians trained in percutaneous, intravascular techniques and procedures.

4Fr 5Fr 6Fr -10 French 9cm 11cm 23cm vascular guide wire introduction catheter, percutaneous femoral introducer sheath kit

Select the number of specifications

Diameter

4F 5F 6F 7F 8F 9F 10F

Length

9cm 11cm 19cm 23cm

Please check the product information you want!
Specifications select

Product Detail

Product:   4Fr 5Fr 6Fr -10 French 9cm 11cm 23cm vascular guide wire introduction catheter, percutaneous femoral introducer sheath kit


Usage:

 The introducer set is intended for percutaneous introduction of guide wire or catheter into the vascular system through introducer needle. The introducer set should be used only by physicians trained in percutaneous, intravascular techniques and procedures.


Feature:


• Comparing with other manufacturers, the special cutting method design of the valve ensures less blood leak in the case of continuous pumping; 

• The front part has high hardness and long taper, making it enter the subcutaneous more smoothly, and even in special cases, the step of skin breaking can be eliminated, reducing the operation time; 

• Hydrophilic coating sheath entering skin tissues greatly reduces the possibility of transradial muscle tension in the patient, thereby avoiding prolonged surgery; 

• Smooth transition between the dilator and sheath;

• Small OD and large lD minirmizes the size ( compromising ease of device passage );

• Seamless guide wire to dilator and dlator to reduce the risks of gaps and arterial damage;

* We can supply kink resistance nitinol guide wire to increase clinician confidence. 


Item No.


TWIST TYPE-Med
Product No.Size(Fr.)Length(cm)GuidewireIntroducer Needle
42.09.10000490.021"*45cm J20G*3.8cm
42.09.100015110.038"*45cm J18G*6.5cm
42.09.100026110.038"*45cm J18G*6.5cm
42.09.100037110.038"*45cm J18G*6.5cm
42.09.100048110.038"*45cm J18G*6.5cm
42.09.100059110.038"*45cm J18G*6.5cm
42.09.1000610110.038"*45cm J18G*6.5cm
42.09.100074190.021"*60cm J20G*3.8cm
42.09.100085230.038"*60cm J18G*6.5cm
42.09.100096230.038"*60cm J 18G*6.5cm
42.09.100107230.038"*60cm J18G*6.5cm
42.09.100118230.038"*60cm J18G*6.5cm
42.09.100129230.038"*60cm J18G*6.5cm
42.09.1001310230.038"*60cm J18G*6.5cm

 

CLICK TYPE-Ter
Product No.Size(Fr.)Length(cm)GuidewireIntroducer Needle
42.09.20000490.021"*45cm J20G X 3.8 cm
42.09.200015110.038"*45cm J18G*6.5cm
42.09.200026110.038"*45cm J18G*6.5cm
42.09.200037110.038"*45cm J18G*6.5cm
42.09.200048110.038"*45cm J18G*6.5cm
42.09.200054190.021"*60cm J20G*3.8cm
42.09.200065230.038"*60cm J18G*6.5cm
42.09.200076230.038"*60cm J18G*6.5cm
42.09.200087230.038"*60cm J18G*6.5cm
42.09.200098230.038"*60cm J18G*6.5cm

 

CLICK TYPE-Coo
Product No.Size(Fr.)Length(cm)GuidewireIntroducer Needle
42.09.30000490.021"*45cm J20G X 3.8 cm
42.09.300015110.038"*45cm J18G*6.5cm
42.09.300026110.038"*45cm J18G*6.5cm
42.09.300037110.038"*45cm J18G*6.5cm
42.09.300044190.021"*60cm J20G*3.8cm
42.09.300055230.038"*60cm J18G*6.5cm
42.09.300066230.038"*60cm J18G*6.5cm
42.09.300077230.038"*60cm J18G*6.5cm



No comment

Product Detail

Product:   4Fr 5Fr 6Fr -10 French 9cm 11cm 23cm vascular guide wire introduction catheter, percutaneous femoral introducer sheath kit


Usage:

 The introducer set is intended for percutaneous introduction of guide wire or catheter into the vascular system through introducer needle. The introducer set should be used only by physicians trained in percutaneous, intravascular techniques and procedures.


Feature:


• Comparing with other manufacturers, the special cutting method design of the valve ensures less blood leak in the case of continuous pumping; 

• The front part has high hardness and long taper, making it enter the subcutaneous more smoothly, and even in special cases, the step of skin breaking can be eliminated, reducing the operation time; 

• Hydrophilic coating sheath entering skin tissues greatly reduces the possibility of transradial muscle tension in the patient, thereby avoiding prolonged surgery; 

• Smooth transition between the dilator and sheath;

• Small OD and large lD minirmizes the size ( compromising ease of device passage );

• Seamless guide wire to dilator and dlator to reduce the risks of gaps and arterial damage;

* We can supply kink resistance nitinol guide wire to increase clinician confidence. 


Item No.


TWIST TYPE-Med
Product No.Size(Fr.)Length(cm)GuidewireIntroducer Needle
42.09.10000490.021"*45cm J20G*3.8cm
42.09.100015110.038"*45cm J18G*6.5cm
42.09.100026110.038"*45cm J18G*6.5cm
42.09.100037110.038"*45cm J18G*6.5cm
42.09.100048110.038"*45cm J18G*6.5cm
42.09.100059110.038"*45cm J18G*6.5cm
42.09.1000610110.038"*45cm J18G*6.5cm
42.09.100074190.021"*60cm J20G*3.8cm
42.09.100085230.038"*60cm J18G*6.5cm
42.09.100096230.038"*60cm J 18G*6.5cm
42.09.100107230.038"*60cm J18G*6.5cm
42.09.100118230.038"*60cm J18G*6.5cm
42.09.100129230.038"*60cm J18G*6.5cm
42.09.1001310230.038"*60cm J18G*6.5cm

 

CLICK TYPE-Ter
Product No.Size(Fr.)Length(cm)GuidewireIntroducer Needle
42.09.20000490.021"*45cm J20G X 3.8 cm
42.09.200015110.038"*45cm J18G*6.5cm
42.09.200026110.038"*45cm J18G*6.5cm
42.09.200037110.038"*45cm J18G*6.5cm
42.09.200048110.038"*45cm J18G*6.5cm
42.09.200054190.021"*60cm J20G*3.8cm
42.09.200065230.038"*60cm J18G*6.5cm
42.09.200076230.038"*60cm J18G*6.5cm
42.09.200087230.038"*60cm J18G*6.5cm
42.09.200098230.038"*60cm J18G*6.5cm

 

CLICK TYPE-Coo
Product No.Size(Fr.)Length(cm)GuidewireIntroducer Needle
42.09.30000490.021"*45cm J20G X 3.8 cm
42.09.300015110.038"*45cm J18G*6.5cm
42.09.300026110.038"*45cm J18G*6.5cm
42.09.300037110.038"*45cm J18G*6.5cm
42.09.300044190.021"*60cm J20G*3.8cm
42.09.300055230.038"*60cm J18G*6.5cm
42.09.300066230.038"*60cm J18G*6.5cm
42.09.300077230.038"*60cm J18G*6.5cm



4Fr 5Fr 6Fr -10 French 9cm 11cm 23cm vascular guide wire introduction catheter, percutaneous femoral introducer sheath kit
The introducer set is intended for percutaneous introduction of guide wire or catheter into the vascular system through introducer needle. The introducer set should be used only by physicians trained in percutaneous, intravascular techniques and procedures.
Long press to look detail
Long by picture save/share
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully

Leave A Message

 

Use the form below to get in touch with the sales team

  • Name

  • E-mail

  • Mobile or Tel Phone

  • Company Name:

  • Country

  • Message

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm
图片展示

Copyright © 2005-2024 Shenzhen X-Way Medical Technology Co., LTD Ltd. All Rights Reserved.

添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了